PRESENTATION VIDEOS

Investigating the Choroid

Chair: Alain Gaudric, MD

  • Topographic variations of choroidal thickness on swept-source OCT in healthy eyes, Alain Gaudric Video
  • Analysis of choroidal morphologic features using swept source OCT, Shozo Sonoda Video
  • Choroidal thickness and its diurnal change in healthy population, Nataliya Semenova Video
  • The relationship of retinal and choroidal thickness to central and peripheral retinal function in Retinitis Pigmentosa, Harvey Uy Video
  • Study of choroidal vascularity index in keratoconus patients vs. healthy controls using swept-source optical coherence tomography-based binarization techniques, Rosa Gutiérrez Bonet Video
  • Discussion Video

Deep Range Imaging of Tumors

Chair: Catherine Favard, MD

  • SS-OCT and SS-AOCT contribution to the diagnosis of choroidal tumors, Catharine Favard Video

  • Optical coherence tomography angiography (OCTA) characteristics of intraocular tumours, Pradeep Sagar Video

  • Swept-source optical coherence tomographic findings in eyes with choroidal osteoma, Maria Oliva Grassi Video

  • OCT angiography as a tool to assess early response to therapy in intra ocular tumours, Pradeep Sagar Video

  • Discussion Video

SSOCT in Glaucoma – 1

Chair: Donald C. Hood, PhD

  • Diagnosing and understanding glaucomatous damage based upon a single ssOCT wide-field scan, Donald C. Hood Video

  • Using ssOCT to minimize reliance on perimetry for glaucoma diagnosis in clinical practice, Jeffrey M. Liebmann Video

  • Role of ocular blood flow in the deep layers of the optic nerve head in glaucoma, Toru Nakazawa Video

  • Optic nerve head characteristics in chronic angle closure glaucoma, Lucy Shen Video

  • Discussion Video

SSOCT in Glaucoma – 2

Chair: Jeffrey M. Liebmann, MD

  • Comparison of scleral ring area, Bruch’s membrane opening area, and optic disc area measured by a swept-source OCT and a spectral-domain OCT in patients with myopia and glaucoma, Ying Dong Video

  • OCT-Angiography analysis of peripapillary flow density in patients with Primary Open-Angle Glaucoma under therapy with Tafluprost, Robert Kromer Video

  • Discussion Video

OCT Insights

Chair: José Ma Ruiz Moreno, MD, PhD

  • Quantification of geographic atrophy associated to AMD: automatic software, José Ma Ruiz Moreno Video

  • Swept Source OCT en-face imaging of vitreous cavity reveals topographic relationship of premacular bursa, Cloquet’s canal, prevascular vitreous fissures and cisterns, Michael Englebert Video

  • Retinal macular involvement in Fabry’s disease detected by Swept Source OCT angiography (SSOCTA) and focal electroretinogram (fERG), Angelo Maria Minella Video

  • Discussion Video

Imaging Uveitis

Chair: Moncef Khairallah, MD

  • SS OCT angiography and uveitic macular edema, Moncef Khairallah Video

  • Role of swept source OCT and OCT angiography in the diagnosis of Not-Dots Uveitis diseases, Alfredo Adán Video

  • Evidence of choriocapillaris hypoperfusion on swept-source optical coherence tomography angiography in multiple evanescent white dot syndrome, Moncef Khairallah Video

  • SS-OCT choroidal thickness measurement in convalescent/quiescent Vogt-Koyanagi-Harada disease, Olga Garcia-Garcia Video

  • Discussion Video

Diabetes and Other Vascular Diseases

Chair: Ramin Tadayoni, MD, PhD

  • Normal to abnormal retinal capillaries in diabetic retinopathy through the lens of OCTA, Ramin Tadayoni Video

  • Characterization of the initial stages of diabetic retinal disease using OCT and OCTA, Jose Cunha-Vas Video

  • Diffuse diabetic macular edema: the various pathogeneses and durable therapies, Avinoam Ophir Video

  • Correlation between choroidal thickness and OCT–A in diabetic patients using Triton swept source OCT, Nihal A. Hassan Video

  • An alternative treatment for retinal artery macroaneurysm evaluated with swept-source optical coherence tomography and angiography, Maria Oliva Grassi Video

  • Discussion Video

GDPR

In accordance with the regulations in force in personal data protection, we inform you that all data provided will be included in a file property of Topcon Medical Systems, established in 111 Bauer Drive, Oakland, NJ 07436, United States with the only purpose of managing your attendance and participation at the conference, for its publication in the necessary documentation which will be edited during or after the preparation of the conference, even for future editions, and/or to manage your hotel reservation, as well as to provide you with information about future editions of the conference, by means of mailing or electronic mail. You may exercise your rights of access, rectification, cancellation and opposition to the treatment of your data, sending a written communication to the address indicated previously, enclosing a photocopy of your ID card or equivalent document. All your personal data will be processed with the maximum confidentiality, according to the Privacy and Security Policy of this company, and with total compliance to the Personal Data Protection Law 15/1999, of 13 December.